Initialized with learning_rate 0.5
step 0000 : loss is 002.45, accuracy on training set 7.81 %, accuracy on test set 10.10 %
step 1000 : loss is 005.37, accuracy on training set 7.81 %, accuracy on test set 9.82 %
step 2000 : loss is 006.46, accuracy on training set 4.69 %, accuracy on test set 11.35 %
step 3000 : loss is 007.29, accuracy on training set 6.25 %, accuracy on test set 10.28 %
step 4000 : loss is 004.34, accuracy on training set 6.25 %, accuracy on test set 8.92 %
step 5000 : loss is 008.25, accuracy on training set 9.38 %, accuracy on test set 8.92 %
step 6000 : loss is 004.49, accuracy on training set 4.69 %, accuracy on test set 9.82 %
step 7000 : loss is 005.16, accuracy on training set 6.25 %, accuracy on test set 9.58 %
step 8000 : loss is 002.77, accuracy on training set 12.50 %, accuracy on test set 9.58 %
step 9000 : loss is 008.34, accuracy on training set 15.62 %, accuracy on test set 8.92 %
step 10000 : loss is 004.80, accuracy on training set 9.38 %, accuracy on test set 11.35 %
Initialized with learning_rate 0.1
step 0000 : loss is 002.37, accuracy on training set 10.94 %, accuracy on test set 10.09 %
step 1000 : loss is 002.47, accuracy on training set 9.38 %, accuracy on test set 10.32 %
step 2000 : loss is 002.48, accuracy on training set 12.50 %, accuracy on test set 10.10 %
step 3000 : loss is 002.54, accuracy on training set 6.25 %, accuracy on test set 10.32 %
step 4000 : loss is 002.52, accuracy on training set 12.50 %, accuracy on test set 9.74 %
step 5000 : loss is 002.62, accuracy on training set 9.38 %, accuracy on test set 9.80 %
step 6000 : loss is 002.73, accuracy on training set 6.25 %, accuracy on test set 10.28 %
step 7000 : loss is 002.44, accuracy on training set 10.94 %, accuracy on test set 9.74 %
step 8000 : loss is 002.33, accuracy on training set 14.06 %, accuracy on test set 10.28 %
step 9000 : loss is 002.42, accuracy on training set 9.38 %, accuracy on test set 10.28 %
step 10000 : loss is 002.38, accuracy on training set 10.94 %, accuracy on test set 8.92 %
Initialized with learning_rate 0.01
step 0000 : loss is 002.40, accuracy on training set 7.81 %, accuracy on test set 10.09 %
step 1000 : loss is 000.02, accuracy on training set 100.00 %, accuracy on test set 96.78 %
step 2000 : loss is 000.04, accuracy on training set 98.44 %, accuracy on test set 97.82 %
step 3000 : loss is 000.06, accuracy on training set 96.88 %, accuracy on test set 98.14 %
step 4000 : loss is 000.00, accuracy on training set 100.00 %, accuracy on test set 98.31 %
step 5000 : loss is 000.00, accuracy on training set 100.00 %, accuracy on test set 98.46 %
step 6000 : loss is 000.01, accuracy on training set 100.00 %, accuracy on test set 98.39 %
step 7000 : loss is 000.00, accuracy on training set 100.00 %, accuracy on test set 98.41 %
step 8000 : loss is 000.00, accuracy on training set 100.00 %, accuracy on test set 98.50 %
step 9000 : loss is 000.02, accuracy on training set 100.00 %, accuracy on test set 98.66 %
step 10000 : loss is 000.00, accuracy on training set 100.00 %, accuracy on test set 98.60 %
Initialized with learning_rate 0.001
step 0000 : loss is 002.42, accuracy on training set 7.81 %, accuracy on test set 8.92 %
step 1000 : loss is 000.20, accuracy on training set 90.62 %, accuracy on test set 93.53 %
step 2000 : loss is 000.10, accuracy on training set 96.88 %, accuracy on test set 95.98 %
step 3000 : loss is 000.04, accuracy on training set 98.44 %, accuracy on test set 96.97 %
step 4000 : loss is 000.04, accuracy on training set 98.44 %, accuracy on test set 97.56 %
step 5000 : loss is 000.01, accuracy on training set 100.00 %, accuracy on test set 97.86 %
step 6000 : loss is 000.02, accuracy on training set 100.00 %, accuracy on test set 97.99 %
step 7000 : loss is 000.08, accuracy on training set 98.44 %, accuracy on test set 98.35 %
step 8000 : loss is 000.01, accuracy on training set 100.00 %, accuracy on test set 98.25 %
step 9000 : loss is 000.06, accuracy on training set 96.88 %, accuracy on test set 98.32 %
step 10000 : loss is 000.03, accuracy on training set 98.44 %, accuracy on test set 98.44 %
Initialized with learning_rate 0.0001
step 0000 : loss is 002.49, accuracy on training set 7.81 %, accuracy on test set 8.92 %
step 1000 : loss is 002.02, accuracy on training set 56.25 %, accuracy on test set 55.78 %
step 2000 : loss is 001.04, accuracy on training set 78.12 %, accuracy on test set 77.89 %
step 3000 : loss is 000.63, accuracy on training set 84.38 %, accuracy on test set 86.23 %
step 4000 : loss is 000.35, accuracy on training set 93.75 %, accuracy on test set 89.03 %
step 5000 : loss is 000.27, accuracy on training set 92.19 %, accuracy on test set 91.00 %
step 6000 : loss is 000.26, accuracy on training set 92.19 %, accuracy on test set 92.17 %
step 7000 : loss is 000.31, accuracy on training set 93.75 %, accuracy on test set 93.00 %
step 8000 : loss is 000.32, accuracy on training set 89.06 %, accuracy on test set 93.71 %
step 9000 : loss is 000.21, accuracy on training set 95.31 %, accuracy on test set 94.21 %
step 10000 : loss is 000.26, accuracy on training set 93.75 %, accuracy on test set 94.64 %
Initialized with learning_rate 1e-05
step 0000 : loss is 002.53, accuracy on training set 10.94 %, accuracy on test set 9.80 %
step 1000 : loss is 002.31, accuracy on training set 9.38 %, accuracy on test set 9.80 %
step 2000 : loss is 002.30, accuracy on training set 14.06 %, accuracy on test set 11.35 %
step 3000 : loss is 002.30, accuracy on training set 9.38 %, accuracy on test set 11.35 %
step 4000 : loss is 002.29, accuracy on training set 12.50 %, accuracy on test set 11.35 %
step 5000 : loss is 002.28, accuracy on training set 12.50 %, accuracy on test set 15.31 %
step 6000 : loss is 002.26, accuracy on training set 25.00 %, accuracy on test set 21.81 %
step 7000 : loss is 002.22, accuracy on training set 34.38 %, accuracy on test set 29.97 %
step 8000 : loss is 002.17, accuracy on training set 45.31 %, accuracy on test set 43.93 %
step 9000 : loss is 002.09, accuracy on training set 51.56 %, accuracy on test set 51.62 %
step 10000 : loss is 001.98, accuracy on training set 54.69 %, accuracy on test set 55.47 %